Products
Contact Us
- Contact Person : Ms. Xiong Vivian
- Company Name : INVT Power System (Shenzhen) Co., Ltd.
- Tel : 86-755-26782664
- Fax : 86-755-26782664
- Address : Guangdong,Shenzhen,Rm. 106, 107, Floor 1, Rm. 5, Building 5, Gaofa Tech Zone, Gaofa Industrial Park, Maotoushan, Beihuan Rd., Nanshan Dist.
- Country/Region : China
- Zip : 518055
Computer UPS(400~1200VA)
Product Detailed
Related Categories:Uninterrupted Power Supply (UPS)
offline UPS 400-1200va
Advanced wide AVR perform
Boost and buck voltage
Spike, surge RFI noise protected
offline UPS 400-1200va
Features:
Advanced wide AVR perform
Boost and buck voltage
Spike, surge ,RFI noise protected
Advanced PWM mosfet technology
Advanced power failure detection
Advanced shutdown for overload and low battery
Ups Auto on when AC back
MODEL | BU400VA | BU500VA | BU650VA | BU750VA | BU800VA | BU1000VA | BU1200VA | |
CAPACITY | VA/W | 240W | 300W | 390W | 450W | 480W | 600W | 720W |
Input | Voltage | 110Vac/220Vac/230Vac/240Vac | ||||||
Voltage range | 75-145v OR 145-280V | |||||||
Frequency | 50Hz/60Hz | |||||||
Output | Frequency | 50Hz /60Hz | ||||||
Voltage | 110Vac/220Vac/230Vac/240Vac | |||||||
Transfer time | <10ms including direction time | |||||||
Wave form | Sine wave under mains supply, square wave under battery operation | |||||||
Battery | BAttery Type and Number | 12v4.5ah*1pc | 12v7ah*1pc | 12v9ah*1pc | 12v7ah*2pcs | 12v9ah*2pcs | ||
Backup Time(at a pc load with 17" monitor) | 5-7 minutes | 8-15 minutes | 15-28minutes | 25-40minutes | 30-50 minutes | |||
Recharge Time | 10 hours | |||||||
Transfer Time | typical | <10MS | ||||||
Indicator | AC MODE | The 1st green LED lighting | ||||||
Battery MODE | The 2nd red LED flashing | |||||||
Fault | Red led lighting | |||||||
Audible Alarm | Battery Mode | Sounding everey 4 seconds | ||||||
Low battery | Sounding everey seconds | |||||||
Overload | ups off | |||||||
PROTECTION | Overload | As load over 130%, UPS is protected in 3 seconds | ||||||
AC input | Fuse for overload & short circuit protection | |||||||
Short circuit | UPS output cut off immediately | |||||||
Battery | Type | Sealed, lead acid maintenance-free | ||||||
protection | Auto-inspection, discharge protection and battery fault caution | |||||||
Battery | Normally battery is charged once every three months, it isn’t less than 6 hours once a time. | |||||||
Physical | Weight(kg) | 4.75 | 6 | 6.5 | 7.5 | 8 | 11 | 12 |
Size (LxWxH)mm | 275*90*138 | 335*103*152 | 345x122x190 | |||||
Note: Product upgradation is a continuous process; hence specifications are subject to change without notice. |
Computer UPS(400~1200VA)
Other products